RetroZone
Update Older Zone Control and VAV Systems
Don't Pull Those Dampers
|
|
Retrofit existing VVT Generation One,
Carrier VVT, and Omnizone systems
(and many other VAV systems) without changing the old dampers.
RetroZone gives you the opportunity to quickly,
easily and profitably update older control systems of any manufacturer.
RetroZone is designed specifically for retrofitting
VVT and Omnizone systems using existing dampers and existing wiring. This
greatly reduces the cost of labor and parts; and allows building tenants
to enjoy the benefits and efficiency of updating older systems, at a low
price. |
|
|
SYSTEM 2000 GEN II |
| CATALOG NUMBER |
DESCRIPTION |
QUANTITY |
|
GEN II |
G/E
OR HP CONTROLLER (SUPPORTS UP TO 10 ZONES - with INTEGRATED CAPACITY CONTROL |
|
|
SYSTEM 2000
GEN II
ZONE KITS |
|
RZKIT |
DIGITAL ZONE KIT
(INCLUDES MODSTAT AND ACTUATOR) |
|
|
101AHDM |
SLAVE DAMPER ACTUATOR |
|
| |
|
BY-PASS DAMPER |
|
BYPRK |
INCLUDES STATIC PRESSURE
CONTROLLER, HAT SECTION, AND ACTUATOR |
|
|
WHEN ORDERING ZONE
KITS AND BY-PASS KITS SPECIFY THE MANUFACTURER OF THE DAMPER BEING
RETROFITTED |
| |
MODCOM
PROVIDES REMOTE
VAV CONTROL FOR ONE ZONED SYSTEM WITH UP TO 20 THERMOSTATS.
UNIVERSAL CONTROLLER FOR G/E OR HEAT PUMP APPLICATIONS WITH INTEGRATED
FOSSIL FUEL CONTROL. |
|
MODCC |
INCLUDES COMMAND
CENTER, OPERATING SOFTWARE, HDLAS SENSOR AND CONFIGURED EXTERNAL MODEM WITH
CABLE |
|
|
RZKIT |
RETROZONE KIT -
INCLUDES MODSTAT AND ACTUATOR |
|
| |
ZONEX COMMANDER PLUS
DESIGNED TO CENTRALIZE CONTROL OF
MULTIPLE ZONED SYSTEMS |
|
ZNXPLUS |
COMMAND CENTER - INCLUDES COMMAND
CENTER, OPERATING SOFTWARE, HDLAS SENSOR, AND CONFIGURED EXTERNAL MODEM WITH
CABLE |
|
|
RMOD |
RMOD IS A UNIVERSAL RELAY MODULE FOR
G/E OR HP APPLICATIONS
USE 1 RMOD RELAY MODULE FOR EACH ZONED UNIT.
EACH ZNXPLUS WILL SUPPORT UP TO 4 RMODS - WITH 20 COMMUNICATING
DEVICES PER RMOD
THE RMOD RELAY MODULE PROVIDES ON BOARD CAPACITY CONTROL
FUNCTIONS, AND A DIGITAL DISPLAY. |
|
|
CZNX |
COMMAND CENTER - WITHOUT SOFTWARE AND
MODEM. FOR SYSTEMS LARGER THAN 20 ZONES USE A MULTIPLEXER. |
|
|
101MUX |
MULTIPLEXER - ALLOWS COMMUNICATION
WITH UP TO 4 COMMAND CENTERS SUPPORTING UP TO 80 ROOF-TOP UNITS, DEVICES OR
ZONES |
|
| |
|
COMPONENTS FOR ALL SYSTEMS |
|
MODSTAT |
COMMUNICATING MODULATING ZONE
THERMOSTAT |
|
|
DIGICOM |
COMMUNICATING STAND-ALONE G/E
THERMOSTAT (2 HEAT/2 COOL) |
|
|
DIGIHP |
COMMUNICATING STAND-ALONE HEAT PUMP
THERMOSTAT (3 HEAT/2 COOL) "E or O" MODE |
|
|
MODSTATRS |
COMMUNICATING MODULATING ZONE
THERMOSTAT - WITH REMOTE SENSOR |
|
|
RZKIT |
RETROZONE KIT - INCLUDES MODSTAT
AND ACTUATOR |
|
|
WPLT |
WALL PLATE - USED WHEN UPGRADING
FROM VVT OR VVHC THERMOSTAT |
|
| |
|
TCP/IP NETWORK DEVICE |
|
TCIP |
TCP/IP
ETHERNET NETWORK SERVER, TO CONNECT
THE ZONEX CONTROL SYSTEM REMOTELY OVER INTERNET OR LAN SYSTEMS,
ZONEX VERSION SOFTWARE IS INCLUDED |
|
|
|
SENDCOM SENSOR
(1 PER EACH
STAND-ALONE UNIT) |
|
SENDCOM |
THE SENDCOM COMMUNICATES RETURN AIR
AND DISCHARGE AIR SENSOR DATA TO
THE COMMANDER CONTROLLER |
|
| |
|
RELAYCOM |
|
RLYCOM |
COMMUNICATING SPDT RELAY. CONTROLS 2 SEPARATE DEVICES ON ONE SCHEDULE.
MULTIPLE RLYCOMS MAY BE UTILIZED, BUT EACH WILL REDUCE THE NUMBER OF
THERMOSTATS FROM THE DEVICE COUNT BY 1 |
|
| |
WIRING - BETWEEN COMMAND CENTER AND
COMMUNICATING THERMOSTATS
USE SHIELDED TWISTED PAIR WIRE IN JOBS
WITH EXTREME ELECTRONIC ACTIVITY OR ELECTRONIC NOISE LEVELS |
|
TWPR |
500 FEET OF TWISTED PAIR
COMMUNICATION WIRE |
|
| SHTP |
1,000 FEET OF
SHIELDED TWISTED PAIR COMMUNICATION WIRE |
|
|
STPR |
1,000 FEET OF STRANDED PLENUM RATED
TWISTED COMMUNICATION WIRE |
|
|
|